Introduction

The following document contains pinout and cable diagrams for the NETBuilder Bridge/Router product line. These diagrams include the following:

NETBuilder II Bridge/Router Console Port Pinouts

The NETBuilder II Bridge/Router contains two serial ports on the Communications Engine Card (CEC). The diagnostic port is used by 3Com engineering when developing and working on the product. The other serial interface on the CEC is the console port, which allows user access to the NETBuilder II bridge/router user interface. The following table contains the pinouts for that port.

     Pin No.    Signal Description
     1          Data Carrier Detect
     2          Receive Data
     3          Transmit Data     
     4          Data Terminal Ready
     5          Signal Ground
     6          Data Set Ready
     7          Request to Send
     8          Clear to Send
     9          Ring Indicator

NETBuilder II Bridge/Router Console Port to Terminal - Cable Diagram

To construct a cable that will attach a piece of data terminal equipment (DTE) such as a terminal or PC to the NETBuilder II console port, use the following cable diagram.
     NETBuilder II    To a DB-9    To a DB-25
     DB-9 (female)    Connector    Connector
     2                3            2
     3                2            3
     1 and 8          7            4
     7                1 and 8      5 and 8
     5                5            7
     4                6            6
     6                4            20

NETBuilder II Bridge/Router Console Port to Modem - Cable Diagram

To construct a cable that will attach a piece of data communications equipment (DCE), such as a modem, to the NETBuilder II Bridge/Router console port, use the following cable diagram.

     NETBuilder II    To a DB-9    To a DB-25
     DB-9 (female)    Connector    Connector
     1                1            8
     2                2            3
     3                3            2
     4                4            20
     5                5            7
     6                6            6
     7                7            4
     8                8            5
     9                9            22

NETBuilder Bridge/Router RS232 Pinout Diagram

The following table provides a pinout diagram for the NETBuilder Bridge/Router wide area network (WAN) interface.

     Pin No.    RS232 Name    Signal Description
      1         AA            Chassis Ground
      2         BA            Transmit Data
      3         BB            Receive Data
      4         CA            Request to Send
      5         CB            Clear to Send
      6         CC            Data Set Ready
      7         AB            Signal Ground
      8         CF            Data Carrier Detect
     15         DB            Transmit Clock
     17         DD            Receive Clock
     20         CD            Data Terminal Ready
     24         DA            External Transmit Clock

NETBuilder II Bridge/Router HSS Module Pinout Diagram

The following table provides a pinout diagram for the NETBuilder II Bridge/Router High Speed Serial (HSS) WAN interface.

     HSS Pin No.    Signal Name      V.35 Pin No./ID    RS232 Pin No.
      1             Chassis Ground   A                   1
      2             TD                                   2
      3             RD                                   3
      4             RTS              C                   4
      5             CTS              D                   5
      6             DSR              E                   6
      7             Signal Ground    B                   7
      8             DCD              F                   8
      9             RDA              R     
     10             RDB              T     
     11             unassigned          
     12             SCRA             V     
     13             SCRB             X     
     14             SDA              P     
     15             TXCI                                15
     16             SDB              S     
     17             RXCI                                17
     18             SCTEA            U     
     19             SCTEB            W     
     20             DTR              H                  20
     21             SCTA             Y     
     22             SCTB             a     
     23             RXCO          
     24             TXCO                                24
     25             unassigned

NETBuilder II Bridge/Router HDWAN (3-Port HSS) Module Pinout Diagram

The following table provides a pinout diagram for the NETBuilder II Bridge/Router HDWAN (3-Port HSS) Module.

     Port (A)   Port (B)   Port (C)   Signal   Input or   Signal           Pin
                                               Output     Description
     57         46         35         GND                 Shield GND       A
     28         17          6         SDB      output     TX data,
                                                           non-inverted    S
     29         18         40         SDA      output     TX data,
                                                           inverted        P
     32         20          8         RDB      input      RX data,
                                                           non-inverted    T
     66         54         42         RDA      input      RX data,
                                                           inverted        R
     58         47         36         RTS      output     Request to
                                                           Send            C
     60         49         37         CTS      input      Clear to Send    D
     26         15          4         DSR      input      Data Set
                                                           (DCE) Ready     E
     24         13          1         DTR      output     Data Terminal
                                                           (DTE) Ready     H
     27         16          5         GND                 Signal GND       B
     61         50         38         DCD      input      Data Carrier
                                                           Detect          F
     34         22         10         SCTB     input      Transmit clock,
                                                           non-inverted    AA
     68         56         44         SCTA     input      Transmit clock,
                                                           inverted        Y
     33         21          9         SCRB     input      Receive clock,
                                                           non-inverted    X
     67         55         43         SCRA     input      Receive clock,
                                                           inverted        V
     25         14          2         LL       output     Local Loop
                                                           Back            L
     59         48          3         RL       output     Remote Loop
                                                           Back            N
     62         51         39         RI       input      Ring Indicator   J
     30         19          7         SCTEB    output     Ext. Transmit
                                                           clock,
                                                           non-inverted    W
     64         53         41         SCTEA    output     Ext. Transmit
                                                           clock,
                                                           inverted        U
     23         12         11         TM       input      Test Mode        NN
     65         52         45         GND                 Shield GND     
     31         63                    NC                  not connected

NETBuilder II Bridge/Router RS449 to X.21 15-pin Adapter Cable Diagram

The following figure provides a cable diagram for a NETBuilder II Bridge/Router RS449 Module to X.21 15-pin Adapter Cable. Use this cable to connect an RS449 connector on the NETBuilder Remote Office or on the NETBuilder II HSS RS449 module to an x.21 DCE device.

NETBuilder II Bridge/Router RS449 to RS-530 Adapter Cable Diagram

The following figure provides a cable diagram for a NETBuilder II Bridge/Router RS449 Module to RS-530 Adapter Cable. Use this cable to connect an RS449 connector on the NETBuilder Remote Office or on the NETBuilder II HSS RS449 module to an x.21 DCE device. Pin assignments for connecting an RS449 female "D" connector and an RS-530 male transition cable.

     Name              Mnemonic   RS449 Pin   Pin    Mnemonic   RS-530 Name
     Shield            -           1           1     -          Shield
     Send Data         SDA         4           2     BA (A)     Transmitted Data
                       SDB        22          14     BA (B)     
     Receive Data      RDA         6           3     BB (A)     Received Data
                       RDB        24          16     BB (B)     
     Request to Send   RSA         7           4     CA (A)     Request to Send
                       RSB        25          19     CA (B)     
     Clear to Send     CSA         9           5     CB (A)     Clear to Send
                       CSB        27          13     CB (B)     
     Data Mode         DMA        11           6     CC (A)     DCE Ready
                       DMB        29          22     CC (B)     
     Terminal Ready    TRA        12          20     CD (A)     DTE Ready
                       TRB        30          23     CD (B)     
     Signal Ground     SG         19           7     AB         Signal Ground
     Receiver Ready    RRA        13           8     CF (A)     Received Line
                       RRB        31          10     CF (B)     Signal Detector
     Send Timing       STA         5          15     DB (A)     Transmit Signal
                       STB        23          12     DB (B)     Element timing
                                                                 (DCE source)
     Receive Timing    RTA         8          17     DD (A)     Receiver Signal
                       RTB        26           9     DD (B)     Element timing
                                                                 (DCE source)
     Terminal Timing   TTA        17          24     DA (A)     Transmit Signal
                       TTB        35          11     DA (B)     Element Timing
                                                                 (DTE source)

NETBuilder II Bridge/Router RS449 Module Pinout Diagram

The following table provides a pinout diagram for the NETBuilder II Bridge/Router RS449 Module.

Note: RS449 is the specification for the 37-pin physical connector while RS422 is the electrical specification for balanced signaling. Our interface does RS422 signaling on an RS449 physical interface.

     Pin No.    Signal     Signal Description
      1         Shield     Chassis Ground
      2         SI         Signal Rate Indicator
      3                    spare
      4         SD (A)     Send Data
      5         ST (A)     Send Timing
      6         RD (A)     Receive Data
      7         RS (A)     Request to Send
      8         RT (A)     Receive Timing
      9         CS (A)     Clear to Send
     10         LL         Local Loopback
     11         DM (A)     Data Mode
     12         TR (A)     Terminal Ready
     13         RR (A)     Receiver Ready
     14         RL         Remote Loopback
     15         IC         Incoming Call
     16         SF/SR+     Select Frequency/Signal Rate Selector
     17         TT (A)     Terminal Timing
     18         TM         Test Mode
     19         SG         Signal Ground
     20         RC         Receive Common
     21                    spare
     22         SD (B)     Send Data
     23         ST (B)     Send Timing
     24         RD (B)     Received Data
     25         RS (B)     Request to Send
     26         RT (B)     Receive Timing
     27         CS (B)     Clear to Send
     28         IS         Terminal In Service
     29         DM (B)     Data Mode
     30         TR (B)     Terminal Ready
     31         RR (B)     Receiver Ready
     32         SS         Select Standby
     33         SQ         Signal Quality
     34         NS         New Signal
     35         TT (B)     Terminal Timing
     36         SB         Standby Indicator
     37         SC         Send Common

NETBuilder II Bridge/Router HSSI (High Speed Serial Interface) Module Pinouts

The following table provides a pinout diagram for the NETBuilder II Bridge/Router HSSI Module.

     Signal Name         Mnemonic   Pin No.   Pin No.   Direction
                                    (+side)   (- side)
     Signal Ground       SG          1        26        -
     Receive Timing      RT          2        27        in
     DCE Available       CA          3        28        in
     Receive Data        RD          4        29        in
     Loopback Request    LC          5        30        in
     Send Timing         ST          6        31        in
     Signal Ground       SG          7        32        -
     DTE Available       TA          8        33        out
     Terminal Timing     TT          9        34        out
     Loopback Circuit A  LA         10        35        out
     Send Data           SD         11        36        out
     Loopback Circuit B  LB         12        37        out
     Signal Ground       SG         13        38        -
     5 ancillary to DCE             14-18     39-43     out
     Signal Ground       SG         19        44        -
     5 ancillary to DCE             20-24     45-49     in
     Signal Ground       SG         25        50        -